Methodology No. KH_PM009
Sectoral scope 3. Energy demand
Title Energy Saving by Introduction of High Efficiency Firewood Cookstove to Replace Traditional Cookstove
Summaries GHG emission reduction measures : The proposed project activity aims at reducing the use of and demand for non-renewable biomass that would have been used for cooking by distributing improved cookstove (ICS, project cookstove) to households and/or communities.
Calculation of reference emissions : Reference emissions are calculated by using the following parameters: Quantity of fuel used per day for each project device of type i during the period p (tonnes or m3/day); Efficiency of project devices of type i in the period p (fraction); Efficiency of reference devices that are replaced by project devices (fraction); Net calorific value of project fuel used in project device type i (TJ/m3); Number of commissioned project devices of type i during the period p (number); Proportion of commissioned project devices of type i during the period p (fraction); Days of the monitoring period during the period p (number); CO2 emission factor for wood fuel use (tCO2/TJ); Non-CO2 emission factor for wood fuel use (tCO2/TJ); Fraction of woody biomass that can be established as non-renewable biomass (fraction); Discount factor to account for the potential source of emissions which may occur due to the use of biomass by non-project households/communities.
Calculation of project emissions : Project emissions are calculated by using the following parameters: Quantity of fuel used per day for each project device of type i during the period p (tonnes or m3/day); Net calorific value of project fuel used in project device type i (TJ/m3); Number of commissioned project devices of type i during the period p (number); Proportion of commissioned project devices of type i during the period p (fraction); Days of the monitoring period during the period p (number); CO2 emission factor for wood fuel use (tCO2/TJ); Non-CO2 emission factor for wood fuel use (tCO2/TJ); Fraction of woody biomass that can be established as non-renewable biomass (fraction); Discount factor to account for the potential source of emissions which may occur due to the use of biomass by non-project households/communities.
Monitoring parameters : Quantity of fuel used per day for each project device of type i during the period p (tonnes or m3/day); Number of commissioned project devices of type i during the period p (number); Proportion of commissioned project devices of type i during the period p (fraction); Days of the monitoring period during the period p (number); Fraction of woody biomass that can be established as non-renewable biomass (fraction); Efficiency of project devices of type i in the period p (fraction)
Status Public inputs closed
Methodology Proponent Tokyo Carbon Management Ltd (TCM)
Proposed Methodology
Public inputs