Methodology No. | KH_AM005 |
---|---|
Proposed Methodology No. | KH_PM005 |
Sectoral scope | 3. Energy demand |
Title | Installation of inverters to distribution pumps in water treatment plant |
Summaries |
GHG emission reduction measures : Introduction of inverter to constant-speed pumps for water distribution in water treatment plant leads to a reduction of electricity consumption by pumps and GHG emissions accordingly. Calculation of reference emissions : Reference emissions are calculated with the monitored electricity consumption of project pumps, the ratio of ECR of reference and project pumps, and the CO2 emission factor for consumed electricity. Calculation of project emissions : Project emissions are calculated with the monitored electricity consumption of project pumps and the CO2 emission factor for consumed electricity. Monitoring parameters : Electricity consumption of project pumps |
Version Number | Ver1.0 |
Status | Valid |
Methodology Proponent | Institute for Global Environmental Strategies |
Approved Methodology | |
Proposed Methodology | |
Public inputs |
|
Date of approval | 21 Feb 20 |