Methodology : VN_AM006 Ver1.0

Methodology No. VN_AM006
Proposed Methodology No. VN_PM008
Sectoral scope 3. Energy demand
Title Introduction of air conditioning system equipped with inverters
Summaries GHG emission reduction measures : This methodology applies to the project that aims for saving energy by introducing air-conditioning system with inverter for cooling in Vietnam.
Calculation of reference emissions : GHG emissions associated with electricity consumption of reference air conditioning system are calculated based on the monitored electricity consumption of project air conditioning system, the ratio of COPs of reference/project air conditioning system, and the CO2 emission factor of the electricity consumed by project air conditioning system.
Calculation of project emissions : GHG emissions associated with electricity consumption of project air conditioning system are calculated based on the monitored electricity consumption of project air conditioning system and the CO2 emission factor of the electricity consumed by project air conditioning system.
Monitoring parameters : Electricity consumption of outdoor unit of project air conditioning system; Total electricity consumption of indoor units of project air conditioning system
Version Number Ver1.0
Status Valid
Methodology Proponent NTT DATA INSTITUTE OF MANAGEMENT CONSULTING, INC.
Approved Methodology
Proposed Methodology
Public inputs
  • 17 Aug 16   -  31 Aug 16
Date of approval 20 Oct 16