Methodology : VN_AM005 Ver1.0

Methodology No. VN_AM005
Proposed Methodology No. VN_PM006
Sectoral scope 2. Energy distribution
Title Installation of energy efficient transformers in a power distribution grid
Summaries GHG emission reduction measures : Installation of energy efficient transformers (transformers with amorphous metal core) in a power distribution grid reduces no-load losses by transformers, which leads to reduction of losses for grid electricity, thus reduction of GHG emissions.
Calculation of reference emissions : Reference emissions are calculated by no-load losses of the reference transformer, blackout rate and CO2 emission factor of the grid.
Calculation of project emissions : Project emissions are calculated by no-load losses of the project transformer, maximum allowable uncertainty for the no-load losses of the project transformer, blackout rate and CO2 emission factor of the grid.
Monitoring parameters : Energizing time of the project transformer
Version Number Ver1.0
Status Valid
Methodology Proponent YUKO-KEISO Co., Ltd., Mitsubishi UFJ Morgan Stanley Securities Co., Ltd.
Approved Methodology
Proposed Methodology
Public inputs
  • 16 Jul 15   -  30 Jul 15
Date of approval 03 Sep 15