Methodology No. | TH_AM015 |
---|---|
Proposed Methodology No. | TH_PM018 |
Sectoral scope | 3. Energy demand |
Title | Introduction of High Efficiency Electrolyzer in Caustic Soda Production Plant |
Summaries |
GHG emission reduction measures : Installing ion-exchange membrane electrolyzer, which reduces electricity resistance of the electrolyzer unit and achieves electricity consumption reduction in the caustic soda process. This methodology applies to the project that introduces high efficiency electrolyzer in caustic soda production plant. Calculation of reference emissions : Reference emissions are GHG emissions from using reference electrolyzer, calculated with electricity consumption of project electrolyzer, ratio of the performance guaranteed values of specific electricity consumptions (SECs) of reference/project electrolyzers and CO2 emission factor for consumed electricity. Calculation of project emissions : Project emissions are GHG emissions from using project electrolyzer, calculated with electricity consumption of project electrolyzer and CO2 emission factor for electricity consumed. Monitoring parameters : Electricity consumption of project electrolyzer |
Version Number | Ver1.0 |
Status | Valid |
Methodology Proponent | AGC Inc.; AGC Chemicals (Thailand) Co.,Ltd. |
Approved Methodology | |
Proposed Methodology | |
Public comments |
|
Date of approval | 20 Sep 21 |