Methodology No. | MN_PM006 |
---|---|
Sectoral scope | 1. Energy industries (renewable-/non-renewable sources) |
Title | Installation of solar photovoltaic system and battery energy storage system |
Summaries |
GHG emission reduction measures : Displacement of grid electricity by installation and operation of solar PV system(s), EMS(s) and BESS(s). Calculation of reference emissions : Reference emissions are calculated based on the amount of grid electricity displaced by the project multiplied by the conservative emission factor of the grid. Calculation of project emissions : Project emissions from a solar PV system(s) and BESS(s) are assumed to be zero, and the quantity of auxiliary electricity for maintaining BESS operation is the project emissions. Monitoring parameters : Monitoring parameters are as follows: [Option 1: PV system(s) and BESS(s) are co-located] Quantity of electricity supplied from the solar PV- BESS system(s) to the grid; Quantity of auxiliary electricity to maintain BESS(s), [Option 2: PV system(s) and BESS(s) are not co-located] Quantity of electricity generated by solar PV system(s); Quantity of PV-derived electricity sent from the grid to BESS(s) for charging; Quantity of PV-derived electricity discharged from BESS(s) to the grid; Quantity of auxiliary electricity to maintain BESS(s) |
Status | Public inputs closed |
Methodology Proponent | Pacific Consultants Co., Ltd. |
Proposed Methodology | |
Public inputs |
|