| Methodology No. | VN_AM013 |
|---|---|
| Proposed Methodology No. | VN_PM019 |
| Sectoral scope | 3. Energy demand |
| Title | Energy saving by introduction of high-efficiency double suction volute pumps in water supply system |
| Summaries |
GHG emission reduction measures : High-efficiency double suction volute pump is introduced in water supply system to save energy, which leads to GHG emission reductions. Calculation of reference emissions : Reference emissions are GHG emissions from power consumption by reference pumps, calculated with the monitored power consumption of project pumps, ratio of pump efficiency of reference/project pumps and CO2 emission factor for consumed electricity. Calculation of project emissions : Project emissions are GHG emissions from power consumption by project pumps, calculated with the monitored power consumption of project pumps and CO2 emission factor for consumed electricity. Monitoring parameters : Electricity consumption of project pumps and the amount of fuel consumption and the amount of electricity generated by captive power, where applicable. |
| Version Number | Ver1.0 |
| Status | Valid |
| Methodology Proponent | Yokohama Water Co., Ltd. |
| Approved Methodology | |
| Proposed Methodology | |
| Public inputs |
|
| Date of approval | 29 Aug 18 |