Methodology : CR_AM003 Ver1.0

Methodology No. CR_AM003
Proposed Methodology No. CR_PM003
Sectoral scope 3. Energy demand
Title Installation of Electric Heat Pump Type Water Heater for Hot Water Supply Systems
Summaries GHG emission reduction measures : Reducing fossil fuel consumption with introducing (an) electric heat pump type water heater(s).
Calculation of reference emissions : Calculated by the net supplied heating energy for hot water supplied for utilization in the project building, efficiencies of the reference equipment (boiler) and CO2 emission factor of fuel.
Calculation of project emissions : Calculated based on the monitored electricity consumption by the electric heat pump type water heater(s) and its auxiliary electric equipment and fuel consumption by auxiliary boiler if applicable.
Monitoring parameters : Electricity consumed by the project electric heat pump type water heater(s), electricity consumed by auxiliary electric equipment of the electric heat pump type water heater system (e.g., water pumps), fuel consumption of project auxiliary boiler where applicable, average water temperature flowing from tap water and/or well to inlet of supply water heater system, average water temperature flowing from outlet of supply water heater system to utilization side, quantity of water flowing from tap water and/or well to inlet of supply water heater system, electricity imported from the grid, where applicable, operating time of captive electricity generator, where applicable, and the amount of fuel consumed and/or the amount of electricity generated by captive power, where applicable.
Version Number Ver1.0
Status Valid
Methodology Proponent NTT DATA INSTITUTE OF MANAGEMENT CONSULTING, INC.
Approved Methodology
Proposed Methodology
Public inputs
  • 20 Sep 17   -  04 Oct 17
Date of approval 12 Mar 18