Methodology No. | VN_AM012 |
---|---|
Proposed Methodology No. | VN_PM018 |
Sectoral scope | 3. Energy demand |
Title | Energy Saving by Introduction of Heat Recovery Electric Heat Pump |
Summaries |
GHG emission reduction measures : HREHP is introduced to save energy, which leads to GHG emission reductions. Calculation of reference emissions : Reference emissions are GHG emissions from using reference equipment for heating energy generation (boiler or electric heater) and air-cooled chiller for cooling energy generation. Reference emissions for heating energy generation are calculated with power consumption of project HREHP(s), rated electricity consumption of project HREHP, rated heating capacity of project HREHP, efficiency of the reference equipment for heating energy generation and CO2 emission factor for the reference equipment for heating energy generation. Reference emissions for cooling energy generation are calculated with power consumption of project HREHP(s), rated electricity consumption of project HREHP, rated cooling capacity of project HREHP, efficiency of the reference equipment for cooling energy generation (COP) and CO2 emission factor for electricity consumed. Calculation of project emissions : Project emissions are GHG emissions from using project HREHP(s), calculated with power consumption of project HREHP(s) and CO2 emission factor for electricity consumed. Monitoring parameters : Power consumption of project HREHP(s); The amount of fuel consumption and the amount of electricity generated by captive power, where applicable |
Version Number | Ver1.0 |
Status | Valid |
Methodology Proponent | HOYA Corporation |
Approved Methodology | |
Proposed Methodology | |
Public inputs |
|
Date of approval | 29 Aug 18 |